ALLIED CORPORATION -- SULFURIC ACID CONCENTRATED -- 6810-00-975-0707
=====================  Product Identification  =====================

Product ID:SULFURIC ACID CONCENTRATED
MSDS Date:10/19/1993
FSC:6810
NIIN:00-975-0707
=== Responsible Party ===
Company Name:ALLIED CORPORATION
Address:COLUMBIA RD AND PARK AVE
Box:1087R
City:MORRISTOWN
State:NJ
ZIP:07960
Country:US
Info Phone Num:800-631-8050
Emergency Phone Num:800-631-8050
CAGE:OLYW2
=== Contractor Identification ===
Company Name:ALLIED CORPORATION, CHEMICAL SECTOR
Box:1139R
City:MORRISTOWN
State:NJ
ZIP:07960
Country:US
Phone:201-455-2000
CAGE:OLYW2
Company Name:ALLIED-SIGNAL INC
Address:Box:2332R
City:MORRISTOWN
State:NJ
ZIP:07962-2332
Country:US
Phone:201-455-4414
CAGE:1L164
Company Name:HONEYWELL INTL INC ENVIRONMENTAL SYSTEMS AND SERVICES
Address:101 COLUMBIA RD
Box:City:MORRISTOWN
State:NJ
ZIP:07962
Country:US
Phone:973-455-3922
CAGE:70308
Company Name:LOS ANGELES CHEMICAL CO
Address:4545 ARDINE ST
Box:1987
City:SOUTH GATE
State:CA
ZIP:90280
Country:US
Phone:213-562-9500
CAGE:75656

=============  Composition/Information on Ingredients  =============

Ingred Name:SULFURIC ACID (SARA III)
CAS:7664-93-9
RTECS #:WS5600000
Fraction by Wt: 93-98% %
Other REC Limits:NONE SPECIFIED
OSHA PEL:1 MG/M3
ACGIH TLV:1 MG/M3; 9192
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:WATER
CAS:7732-18-5
RTECS #:ZC0110000
Fraction by Wt: BALANCE
Other REC Limits:NONE SPECIFIED

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:LD50 ORAL = 2140 MG/KG (RAT)
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:YES
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:PRODUCT IS A STRONG MINERAL ACID, AN
    OXIDIZING AGENT, AND A DEHYDRATING AGENT THAT IS RAPIDLY DAMAGING
    TO ALL HUMAN TISSUE WITH WHICH IT COMES IN CONTACT. INGESTION MAY
    CAUSE SEVERE INJURY OR DEATH. E YE CONTACT PRODUCES SEVERE OR
    PERMANENTINJURY. INHALATION OF MISTS CAN DAMAGE BOTH UPPER
    RESPIRATORY TRACT AND LUNGS.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
    CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
    CARCINOGENS.
Effects of Overexposure:SKIN: IRRITATION, CORROSIVE BURNS. EYES:
    IRRITATION, CORNEAL BURNS, CONJUCTIVITIS. INGESTION: IRRITATION,
    CORROSIVE BURNS TO MOUTH, THROAT, AND STOMACH. CAN BE FATAL IF
    SWALLOWED. INHALATION: IRRITATI ON AND BURNS TO UPPER RESPIRATORY
    SYSTEMAND LUNGS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:INHALATION: REMOVE TO FRESH AIR. IF NOT BREATHING, GIVE CPR.
    IF BREATHING IS DIFFICULT, GIVE OXYGEN. EYES: IMMEDIATELY FLUSH
    WITH PLENTY OF WATER FOR AT LEAST 15 MINUTES. SKIN: WASH WITH SOAP
    AND WATE R. REMOVE CONTAMINATED CLOTHING AND SHOES. INGESTION:
    DILUTE WITH WATER OR MILK. DO NOT INDUCE VOMITING. GET MEDICAL
    ATTENTION IN ALL CASES.

=====================  Fire Fighting Measures  =====================

Flash Point:NONFLAMMABLE
Lower Limits:NOT GIVEN
Upper Limits:NOT GIVEN
Extinguishing Media:USE WATER SPRAY/SUITABLE AGENTS FOR ADJACENT TANK;
    DRY CHEMICAL
Fire Fighting Procedures:WEAR APPROVED SCBA WITH FULL FACEPIECE. COOL
    NON-LEAKERS WITH WATER SPRAY.
Unusual Fire/Explosion Hazard:DO NOT ADD WATER OR OTHER LIQUID TO ACID.
    THE ACID, ESPECIALLY WHEN DILUTED WITH WATER CAN REACT WITH METALS
    TO LIBERATE FLAMMABLE HYDROGEN GAS.

==================  Accidental Release Measures  ==================

Spill Release Procedures:PROVIDE VENTILATION. STOP LEAK IF CAN DO SO
    WITHOUT RISK. CLEANUP PERSONNEL NEED PROTECTION AGAINST INHALATION
    OR CONTACT. KEEP UPWIND. CONTAIN SPILL. MINOR LEAKS OR SPILLS CAN
    BE DILUTED WITH WATER A ND NEUTRALIZED. CONTACT PROPER AUTHORITIES.
Neutralizing Agent:SODA ASH, LIME

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE FULL PROTECTIVE EQUIPMENT. STORE
    IN COOL, WELL-VENTILATED AREA AWAY FROM COMBUSTBLE/REACTVE
    CHEM.VENT CNTNRS IN HOT WEATHR TO AVOID H2 BUILD-UP.
Other Precautions:SAFETY SHOWER AND EYEWASH FACILITIES SHOULD BE
    AVAILABLE NEARBY SULFURIC ACID HANDLING EQUIPMENT. DO NOT ADD WATER
    TO ACID. ALWAYS ADD ACID TO COLD WATER CAUTIOUSLY WITH AGITATION.
    PACKAGING/ UNLOADIN G AREA NEEDS EXHAUST SYSTEM.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF VENTILATION DOES NOT MAINTAIN INHALATION
    EXOSURES BELOW PEL (TLV), USE NIOSH/MSHA APPROVED RESPIRATOR AS PER
    CURRENT 29 CFR 1910.134, INSTRUCTIONS/WARNINGS AND NIOSH RESPIRATOR
    SELECTION.
Ventilation:SUFFICIENT TO REDUCE ACID MIST BELOW TLV LEVELS. MAY
    REQUIRE MECHANICAL EXHAUST.
Protective Gloves:RUBBER, PVC
Eye Protection:CHEMICAL SAFETY GOGGLES, FACESHIELD
Other Protective Equipment:ACID RESISTANT APRON, PROTECTIVE CLOTHING,
    BOOTS/JACKET/TROUSERS
Work Hygienic Practices:WASH WITH SOAP AND WATER AFTER HANDLING PRODUCT
    AND BEFORE EATING DRINKING OR SMOKING.
Supplemental Safety and Health

==================  Physical/Chemical Properties  ==================

HCC:C1
Boiling Pt:=281.1C, 538.F
Melt/Freeze Pt:=-33.9C, -29.F
Vapor Pres:< 1 @ 100F
Spec Gravity:1.835
Solubility in Water:COMPLETE
Appearance and Odor:OILY, COLORLESS, HYGROSCOPIC, OILY LIQUID WITH NO
    ODOR.   .
Percent Volatiles by Volume:100 %

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
OXIDIZERS, FLAMMABLE MATERIALS, REDUCING MATERIALS, CARBIDES,
    CHLORATES, SULFIDES, ALLYL COMPOUNDS, ALDEHYDES
Stability Condition to Avoid:HEATING >300C,572F, MOISTURE
Hazardous Decomposition Products:SULFUR TRIOXIDE, SULFUR DIOXIDE,
    HYDROGEN SULFIDE, HYDROGEN GAS

====================  Disposal Considerations  ====================

Waste Disposal Methods:PREVENT WASTE FROM CONTAMINATING SURROUNDING
    ENVIRONMENT. DISCARD ANY PRODUCT, RESIDUE, DISPOSAL CONTAINER OR
    LINER IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.