STARTEX CHEMICAL, INC -- ACETONE -- 6810-01-003-0262
=====================  Product Identification  =====================

Product ID:ACETONE
MSDS Date:05/31/1989
FSC:6810
NIIN:01-003-0262
=== Responsible Party ===
Company Name:STARTEX CHEMICAL, INC
Box:687
City:CONROE
State:TX
ZIP:77305
Country:US
Info Phone Num:409-539-6244
Emergency Phone Num:800-424-9300(CHEMTREC)
CAGE:OYFV5
=== Contractor Identification ===
Company Name:STARTEX CHEMICAL INC
Address:5 HACKBERRY LANE
Box:3087
City:CONROE
State:TX
ZIP:77305
Country:US
Phone:800-424-9300(CHEMTREC)/936-539-6244
CAGE:OYFV5

=============  Composition/Information on Ingredients  =============

Ingred Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 100%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:750PPM/1000STEL;9596
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:TLV:750PPM
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EYE:CAUSES
    IRRIT,REDNESS,TEARING.SKIN:CAN CAUSE SLIGHT
    IRRIT.BREATHING:EXCESSIVE INHAL OF VAP CAN CAUSE NASAL & RESP
    IRRIT,CNS EFFECTS INCLUDE DIZZ,WEAK,FTG,NAU,HEAD,POSSIBLE
    UNCONSC,EVEN DEATH.SWALLO W:CAN CAUSE GI IRRIT,NAU,VOMIT,DIARR.
Effects of Overexposure:OVEREXPO TO THIS MATL(OR ITS COMPONENTS)HAS
    BEEN SUGGESTED AS CAUSE OF FOLLOWING EFFECTS IN LABORATORY
    ANIMALS:KIDNEY DAMAGE,EYE DAMAGE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

=======================  First Aid Measures  =======================

First Aid:SKIN:THOROUGHLY WASH EXPO AREA W/SOAP/WATER.REMOVE CONTAM
    CLOTH.EYE:FLUSH W/LG AMTS OF WATER,LIFTING UPPER/LOWER LIDS
    OCCASIONALLY.GET MED ATTN.SWALLOWED:IMMED DRINK 2 GLASSES OF
    WATER.INDUCE VOMIT BY  EITHER GIVING IPECAC SYRUP OR BY PLACING
    FINGER @BACK OF THROAT.NEVER GIVE ANYTING BY MOUTH IF UNCONSC.GET
    MED ATTN IMMED.BREATHED:AFFECTED REMOVE TO FRESH AIR.BREATH DIFFI
    ADMIN OXY;STOP GIVE (SUPP)

=====================  Fire Fighting Measures  =====================

Flash Point:-1F,-18C
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:2.6
Upper Limits:12.8
Extinguishing Media:ALCOHOL FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS W/FULL
    FACEPIECE OPERATED IN POSITIVE PRESSURE DEMAND MODE WHEN FIGHTING
    FIRES.
Unusual Fire/Explosion Hazard:HIGHLY VOLATILE,READILY GIVES OFF VAP
    WHICH MAY TRAVEL ALONG GROUND/MOVE BY VENTI,IGN BY PILOT
    LIGHT/OTHER FLAME/SPARK/HEATER/SMOKE/ELECTRIC MOTOR/STATIC(SUPPL)

==================  Accidental Release Measures  ==================

Spill Release Procedures:SM:ABSORB ON PAPER,VERMI,FLOOR ABSORBENT,OTHER
    ABSORBENT MATL.TRANSF TO HOOD.LG:REMOVE ALL IGN SOURCES.PESON NOT
    WEAR PROT EQPMT EXCLUDED FRM AREA TIL CLEANUP COMPLETED.STOP SPILL
    @SOURCE.DIKE-PREVENT  SPREADING.PUMP TO SALVG TK.REMAIN LIQ USE
    (SUPPL)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:CNTNR OF MATL MAY BE HAZ WHEN
    EMPTIED.SINCE EMPTIED CNTNR RETAIN PRODUCT
    RESIDUES(VAP/LIQ/SOLID)ALL HAZ PRECAUT GIVEN IN DATASHEET MUST BE
    OBSERVED.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:IF WORKPLACE EXPO PROD/COMPO LIMIT
    EXCEEDED,NIOSH/MSHA APPROV AIR SUPPLIED RESP ADVISED IN ABSENCE OF
    PROPER ENVIRO CNTRL.OSHA REGS ALSO PERMIT OTHER NIOSH/MSHA
    RESP(-PRESS TYP)UNDER SPEC CONDITIONS.E NGINEER/ADMIN CNTRL
    IMPLEMENTED-RED EXPO
Ventilation:PROVIDE SUFFICIENT MECHANICAL(GEN &/OR LOC
    EXHAU)VENTILATION TO MAINTAIN EXPO BELOW TLV.
Protective Gloves:RESIST GLOVES:NAT RUBB,NEOPRENE,NITRILE
Eye Protection:CHEM SPLASH GOGG,OTHER TYPE OF SAF GLASS
Other Protective Equipment:CONSULT SAFETY EQPMT SUPPLIER FOR RESP/EYE
    PROT.TO PREVENT REP/PROL SKIN CONTACT WEAR IMPERVIOUS CLOTH/BOOTS.
Work Hygienic Practices:LAUNDER CONTAM CLOTH BEF REUSE.
Supplemental Safety and Health
FIRE/EXPLO:DISCHAR,OTHER IGN SOURCES @LOCATION DISTANT FRM MATL HNDLG
    PT.NEVER USE WELD/CUT TORCH ON/NEAR DR(EVEN EMPTY)-PROD(EVEN
    RESIDUE)CAN IGN EXPLO.ALL 5GAL PAILS/LG METAL CNTNR INCLUDE TANK
    CARS /TRUCKS GROUND &/OR BOND WHEN TRANSF. 1STAID:ART RESP.KEEP
    WARM/QUIET.GET MED ATTN. SPILL:SAND,CLAY,EARTH,FLOOR ABSORBEN

==================  Physical/Chemical Properties  ==================

HCC:F2
Boiling Pt:B.P. Text:133F,56C
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:181.70 NP
Vapor Density:2.0
Spec Gravity:0.785-0.788
pH:NP
Viscosity:NP
Evaporation Rate & Reference:14.40, N,BUTYL ACETATE=1
Solubility in Water:NP
Appearance and Odor:FLAMM LIQUID
Percent Volatiles by Volume:100.00
Corrosion Rate:NP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
AVOID CONTACT W/STRONG OXIDIZING AGENTS,STRONG ALKALIES,STRONG MINERAL
    ACIDS.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:MAY FORM TOXIC MATERIALS:CARBON
    DIOXIDE, CARBON MONOXIDE, VARIOUS HYDROCARBONS, ETC.

====================  Disposal Considerations  ====================

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
    AND FEDERAL REGULATIONS.

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.